Day: Select which day or days of the week the schedule is to apply to here.
To remove the scheduling for a particular day, the time for that day must
be reset by setting the start time to the same as the stop time. If the line
"all" is used, all days in the period are set for these times.
Time period: The start and stop time for the selected day for scheduling
are selected here.
Adjusting: How much the heating curve is to be offset in relation to menu
1.1 during scheduling is set here. If the rooms sensor is installed the desired
room temperature is set in °C.
Conflict: If two settings conflict with each other a red exclamation mark
is displayed.
TIP
If you wish to set similar scheduling for every day of the week start by
filling in “all” and then changing the desired days.
Caution
If the stop time is before the start time it means that the period extends
past midnight. Scheduling always starts on the date that the start time is
set for.
Changes of temperature in accommodation take time. For example, short
time periods in combination with underfloor heating will not give a no-
ticeable difference in room temperature.
advanced
DGYDQFHG
KHDWLQJ FXUYH
H[WHUQDO DGMXVWPHQW
PLQ IORZ OLQH WHPS
URRP VHQVRU VHWWLQJV
RZQ FXUYH
SRLQW RIIVHW
Menu advanced has or ange text and
is intended for the advanced user. This
menu has several sub-menus.
heating curve Setting the heating
curve slope.
external adjustment Setting the heat
curve offset when the external contact
is connected.
min. flow line temp. Setting minim-
um permitted flow line temperature.
Menu
1.9
room sensor settings Settings regarding the room sensor.
own curve Setting own heat curve.
point offset Setting the offset of the heating curve at a specific outdoor
temperature.
NIBE™ VVM 310Chapter 3 | VVM 310 – at your service28