TIP
W ait 24 hours before making a new setting, so that the room temperature
has time to stabilise.
If it is cold outdoors and the room temperature is too low, increase the
curve slope by one increment.
If it is cold outdoors and the room temperature is too high, lower the
curve slope by one increment.
If it is warm outdoors and the room temperature is too low, increase the
curve offset by one increment.
If it is warm outdoors and the room temperature is too high, lower the
curve offset by one increment.
external adjustment
H[WHUQDO DGMXVWPHQW 
FOLPDWH V\VWHP
FOLPDWH V\VWHP
FOLPDWH V\VWHP
FOLPDWH V\VWHP
r&
r&
climate system
Setting range: -10 to +10 or desired
room temperature if the room
sensor is installed.
Default value: 0
Menu
1.9.2
Connecting an external contact, for example, a room thermostat or a timer
allows you to temporarily or periodically raise or lower the room temper-
ature. When the contact is on, the heat curve offset is changed by the
number of steps selected in the menu. If a room sensor is installed and
activated the desired room temperature (°C) is set.
If there is more than one climate system the setting can be made separately
for each system.
NIBE™ VVM 310Chapter 3 | VVM 310 at your service32