EasyManua.ls Logo

Nibe VVM 310 - Room Sensor Settings

Nibe VVM 310
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
min. flow line temp.
PLQ IORZ OLQH WHPS 
FOLPDWH V\VWHP
FOLPDWH V\VWHP
FOLPDWH V\VWHP
FOLPDWH V\VWHP
r&
r&
r&
r&




climate system
Setting range: 5-70 °C
Default value: 20 °C
Menu
1.9.3
Set the minimum temperature on the supply temperature to the climate
system. This means that VVM 310 never calculates a temperature lower
than that set here.
If there is more than one climate system the setting can be made separately
for each system.
TIP
The value can be increased if you have, for example, a cellar that you al-
ways want to heat, even in summer.
You may also need to increase the value in "stop heating" menu 4.9.2
"auto mode setting".
room sensor settings
URRP VHQVRU VHWWLQJV 
IDFWRU V\VWHP
FRQWURO URRP VHQVRU V\VW
FRQWURO URRP VHQVRU V\VW
IDFWRU V\VWHP
FRQWURO URRP VHQVRU V\VW
FRQWURO URRP VHQVRU V\VW
factor system
Setting range: 0.0 - 6.0
Default value: 2.0
Menu
1.9.4
Room sensors to control the room temperature can be activated here.
Here you can set a factor that determines how much the supply temperat-
ure is to be affected by the difference between the desired room temper-
33NIBE™ VVM 310Chapter 3 | VVM 310 at your service

Other manuals for Nibe VVM 310

Related product manuals