All settings that are available to the
user (including advanced menus) can
be reset to default values here.
Menu
4.9.4
Caution
After factory setting, personal set-
tings such as heating curves must be
reset.
schedule blocking
The compressor and/or addition in the indoor module can be scheduled
to be blocked for up to two different time periods here.
Menu
4.9.5
When scheduling is active the relevant blocking symbol is shown in the
main menu on the symbol for the indoor module.
DFWLYDWHG
VFKHGXOH VFKHGXOH
DOO
PRQ
WXHV
ZH
WKXU
IUL
VDW
VXQ
VFKHGXOH EORFNLQJ 
7LPH SHULRG %ORFNLQJ'D\
$FWLYDWHG
6FKHGXOH
&RQIOLFW
Schedule: The period to be changed is selected here.
Activated: Scheduling for the selected period is activated here. Set times
are not affected at deactivation.
Day: Select which day or days of the week the schedule is to apply to here.
To remove the scheduling for a particular day, the time for that day must
be reset by setting the start time to the same as the stop time. If the line
"all" is used, all days in the period are set for these times.
Time period: The start and stop time for the selected day for scheduling
are selected here.
NIBE™ VVM 310Chapter 3 | VVM 310 at your service54