Select the average outdoor temperatures in this menu.
You can also set the time over which (filtering time) the average temper-
ature is calculated. If you select 0, the present outdoor temperature is
used.
Caution
It cannot be set "stop additional heat" higher than "stop heating".
Caution
In systems where heating and cooling share the same pipes "stop heating"
cannot be set higher than "start cooling".
degree minute setting
FXUUHQW YDOXH
VWDUW FRPSUHVVRU
VWDUW GLII DGGLWLRQDO KHDW
GLII EHWZHHQ DGGLWLRQDO VWHSV
'0
'0
'0
'0
GHJUHH PLQXWH VHWWLQJ
current value
Setting range: -3000 – 3000
start compressor
Setting range: -1000 – -30
Default value: -60
start diff additional heat
Setting range: 100 – 1000
Default value: 700
diff. between additional steps
Setting range: 0 – 1000
Default value: 100
Menu
4.9.3
Degree minutes are a measurement of the current heating requirement
in the house and determine when the compressor respectively additional
heat will start/stop.
Caution
Higher value on "start compressor" gives more compressor starts, which
increases wear in the compressor. Too low value can give uneven indoor
temperatures.