15 - English
EN
procedure (Paragraph 3.3) or the “enabling code” procedure (Paragraph 3.4). The default setting is ON for both
procedures. To perform the following procedure it is necessary to have a transmitter already memorised in the
receiver.
PROCEDURE 7 - Locking (or release) of memorisations carried out with the “near the control
unit” procedure and/or through the “enabling code”
01. Disconnect the power supply and wait 5 seconds.
5 s
02. Hold down key A of the receiver and simultaneously restore the
power supply: LED B rst emits the signals relative to the memo-
rised transmitters (Chapter 3) then emits a few short orange
ashes: release key A exactly at the end of the 2
nd
orange ash.
+
...