NE200/300 Series Drive User Manual
Chapter 1 Introduction to NE200/300 Series Drive 5
NE300−4T□□□□PB Three-phase 400V Squared torque/normal-duty
application
Power(kW)
2.2
4.0
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
Adapted Motor(kW)
2.2
4.0
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
Output
(V
3Phase 0~Rated input voltage
Current(A
6.0
9.0
13
17
25
32
37
45
60
75
90
110
150
176
210
250
Input
3Phase 380V/440V; 50Hz/60Hz
Range
~
Voltage imbalance ≤3%
Allowable frequency fluctuation ±5%
Current(A
7.0
10.7
15.5
20.5
26
35
38.5
46.5
62
76
92
113
157
180
214
256
Power(kW)
160
185
200
220
250
280
315
355
400
450
500
560
630
710
800
900
Adapted Motor(kW)
Output
(V
3Phase 0~Rated input voltage
Current(A
300
340
380
420
470
540
600
660
730
840
900
950
0
0
0
0
Input
3Phase 380V/440V; 50Hz/60Hz
Range
~
Voltage imbalance ≤3%
Allowable frequency fluctuation ±5%
Current(A
307
345
385*
430*
480*
548*
610*
670*
740*
850*
910*
960*
1170*
1310*
1470*
1650*
* NE300−4T1850P and above products are equipped with external DC reactor as standard.