Questions and Answers

  • H
    hchurchSep 23, 2025
    What to do if Nidec DC Drives show EEPROM error?
    • J
      Joshua MathewsSep 23, 2025
      If your Nidec DC Drives are showing an EEPROM error: 1. Recover factory defaults if function code parameter writing error. 2. Ask for service from supplier, if EEPROM damaged.
  • M
    mason50Aug 25, 2025
    What causes over current in Nidec NE200-2S0015GB DC Drives during acceleration and how to fix it?
    • W
      williamsandreaAug 25, 2025
      Overcurrent during acceleration in Nidec DC Drives can stem from a few reasons. If the acceleration time is too short, increase it. Also, check the input power source for low voltage. Finally, if the drive power rating is too small, choose a drive with higher capacity.
  • J
    Justin FloresAug 25, 2025
    What causes over current at constant-speed in Nidec DC Drives?
    • H
      Harry PearsonAug 26, 2025
      If you're experiencing overcurrent at a constant speed with your Nidec DC Drives, several factors could be the cause. Check the load for any abnormal mutations. Also, verify the input power source isn't experiencing low voltage. Ensure your drive has sufficient power capacity. Finally, if you're using closed-loop vector control, inspect the encoder and its wiring for any sudden disconnections.
  • J
    Joseph SanchezAug 27, 2025
    What to do if Nidec DC Drives show drive overload?
    • V
      Vincent McguireAug 27, 2025
      If your Nidec DC Drives are showing a drive overload, first check the input power source for low voltage. If the load is too heavy, select a drive with a bigger capacity. If the acceleration is too fast, increase the acceleration time. Also, avoid restarting the motor while it's still turning.
  • J
    jhaysAug 27, 2025
    What causes over current in Nidec NE200-2S0015GB during deceleration?
    • N
      Nicole GravesAug 27, 2025
      Overcurrent during deceleration in Nidec DC Drives can occur due to several reasons. If the deceleration time is too short, increase it. If there is a large load inertia, add suitable brake devices. Finally, if the drive power rating is too small, choose a higher capacity drive.
  • M
    martinjenniferSep 16, 2025
    What to do if Nidec NE200-2S0015GB DC Drives show keypad & control board communication interrupted?
    • M
      Ms. Lisa GarciaSep 16, 2025
      If communication between the keypad and control board is interrupted on your Nidec DC Drives, check the connection cable between the keypad and control panel.
  • M
    Melinda RyanSep 13, 2025
    What to do if Nidec NE200-2S0015GB show external terminal fault?
    • V
      Victoria HoganSep 13, 2025
      If your Nidec DC Drives are showing an external terminal fault, check the external input, as the fault likely originates from the external control circuit.
  • A
    Amy CampbellSep 14, 2025
    What to do if Nidec NE200-2S0015GB show Parameter copy Error?
    • A
      Amber ReedSep 15, 2025
      If your Nidec DC Drives are showing a Parameter copy Error: 1. Shorten the cable between Keypad and control board to reduce interference if too long connection cable between keypad and control board leads to interference in parameters transmission. 2. Before downloading, make sure the parameters match the drive, if the downloading parameters do not match the existed parameters in the drive.
  • D
    Daniel HarrellSep 5, 2025
    What to do if Nidec DC Drives show ground fault?
    • J
      Jonathan HansenSep 5, 2025
      If your Nidec DC Drives are indicating a ground fault, it could be due to a short circuit in one of the output phases. Check whether the electric motor insulation is weakening. Also, check whether the wiring between the frequency converter and the electric motor is damaged.
  • B
    Breanna FlemingSep 3, 2025
    What to do if Nidec NE200-2S0015GB show fast current limit fault?
    • D
      Darren StevensSep 3, 2025
      If your Nidec DC Drives are showing a fast current limit fault, it could be due to a load that is too large or a motor blocked to stall, so decrease the load and check the motor and mechanical part status. If the drive power rating is too small, choose a higher power drive. If the drive output circuit loop is grounded or short-circuited, remove the external fault.

Summary

Chapter 1 NE200;300 Product Introduction

1.4 Specifications

Comprehensive technical specifications for NE200 and NE300 drives, covering control modes and features.

Chapter 2 Installation

Chapter 3 Wiring

3.1 Connection of the Product and Peripheral Devices

Diagram and explanation for connecting the drive and peripheral devices.

3.4 Terminal configuration of main circuit

Details the terminal configuration for the main circuit wiring.

3.5 Attention for Main Circuit Wiring

Important notes and precautions for main circuit wiring procedures.

3.6 Control Terminal Wiring

Wiring diagrams and instructions for the control terminals.

Chapter 4 Operation and Display

4.1 Keypad

Description of the drive's keypad, including button functions and indicators.

4.2 Function code viewing and modification

Instructions on how to view and modify function codes and parameters.

Chapter 5 Parameters Brief

F1 Start and Stop

Parameters related to the drive's start and stop control modes.

F3 Vector Control Parameters

Parameters specific to vector control mode operations.

F4 V;F Control Parameters

Parameters for Voltage/Frequency (V/F) control methods.

F5 Motor parameters group

Configuration parameters for matching the drive to the motor characteristics.

F6 Input terminals group

Settings for configuring the functions of digital and analog input terminals.

F7 Output terminals group

Configuration settings for the drive's output terminals.

FC Protection and fault parameters group

Parameters for drive protection and fault handling.

FE Operation interface & display group

Parameters related to the drive's operation interface and display.

FP Protection Parameters

Parameters for setting user passwords and write-in protection.

Chapter 7 Fault information and trouble shooting

7.1 Fault information and solutions.

Lists common faults, possible causes, and corresponding solutions for troubleshooting.

7.3 The general fault diagnosis and solutions

Provides general guidance for diagnosing and resolving common drive abnormalities.

Chapter 8 Routine Repair and Maintenance

8.1 Routine Maintenance

Guidelines for regular maintenance tasks to ensure drive longevity.

Appendix A NE300 Closed-loop Control

Appendix B Modbus Communication Protocol

Appendix E: NE300 Option cards instruction

Resolver PG encoder option instruction

Nidec NE200-2S0015GB Specifications

General IconGeneral
BrandNidec
ModelNE200-2S0015GB
CategoryDC Drives
LanguageEnglish

Related product manuals