What to do if Nidec NE200-2S0015GB DC Drives show output phase loss?
- EefullerSep 8, 2025
If your Nidec DC Drives are showing an output phase loss, check the U-V-W motor wiring. Also, if there is a serious unbalance in output, check the load.

What to do if Nidec NE200-2S0015GB DC Drives show output phase loss?
If your Nidec DC Drives are showing an output phase loss, check the U-V-W motor wiring. Also, if there is a serious unbalance in output, check the load.
What to do if Nidec NE200-2S0015GB DC Drives show load short-circuit?
If your Nidec DC Drives are displaying a load short-circuit error, check whether the electric motor coil is short circuit. If the inverting module IGBT is damaged, ask for the services from manufacturers.
What to do if my Nidec NE200-2S0015GB DC Drives show motor overload?
If your Nidec DC Drives indicate a motor overload, several factors could be responsible. First, check the input power source for any abnormalities. Ensure the motor's rated current is correctly configured in the settings. If the V/F curve isn't suitable, adjust it along with the torque boosting performance. For motors consistently operating with heavy loads at low speeds, consider using a specialized electric motor. Also, verify that neither the motor nor the load is blocked or experiencing sudden, large load changes. Finally, if the motor power is insufficient, use a motor and drive with appropriate power ratings.
What causes bus under voltage during running of Nidec NE200-2S0015GB DC Drives?
A bus under voltage during the operation of Nidec DC Drives is caused by power grid low voltage, so check the input power source.
What to do if Nidec NE200-2S0015GB show fast current limit fault?
If your Nidec DC Drives are showing a fast current limit fault, it could be due to a load that is too large or a motor blocked to stall, so decrease the load and check the motor and mechanical part status. If the drive power rating is too small, choose a higher power drive. If the drive output circuit loop is grounded or short-circuited, remove the external fault.
What to do if my Nidec NE200-2S0015GB show over Voltage in Acceleration?
If your Nidec DC Drives display an overvoltage during acceleration, it could be due to a too short acceleration time, so increase it. Another possible cause is an abnormal power supply, so check the input power source.
What to do if my Nidec NE200-2S0015GB DC Drives show over voltage in constant speed?
If your Nidec DC Drives are showing an overvoltage at constant speed, first check the input power source for abnormalities. If the load inertia is large, add suitable braking devices.
How to fix heat-sink over heat in Nidec NE200-2S0015GB DC Drives?
To resolve heat-sink overheating in Nidec DC Drives, first lower the ambient temperature. If the fan is damaged, replace it. Also, ensure the fan air duct is clear of any blockages.
What to do if my Nidec NE200-2S0015GB DC Drives show over voltage in deceleration?
If your Nidec DC Drives are showing an overvoltage during deceleration, the deceleration time may be too short, so increase it. Also, if the load inertia is large, add suitable brake devices.
What causes over current in Nidec NE200-2S0015GB during deceleration?
Overcurrent during deceleration in Nidec DC Drives can occur due to several reasons. If the deceleration time is too short, increase it. If there is a large load inertia, add suitable brake devices. Finally, if the drive power rating is too small, choose a higher capacity drive.
Comprehensive technical specifications for NE200 and NE300 drives, covering control modes and features.
Diagram and explanation for connecting the drive and peripheral devices.
Details the terminal configuration for the main circuit wiring.
Important notes and precautions for main circuit wiring procedures.
Wiring diagrams and instructions for the control terminals.
Description of the drive's keypad, including button functions and indicators.
Instructions on how to view and modify function codes and parameters.
Parameters related to the drive's start and stop control modes.
Parameters specific to vector control mode operations.
Parameters for Voltage/Frequency (V/F) control methods.
Configuration parameters for matching the drive to the motor characteristics.
Settings for configuring the functions of digital and analog input terminals.
Configuration settings for the drive's output terminals.
Parameters for drive protection and fault handling.
Parameters related to the drive's operation interface and display.
Parameters for setting user passwords and write-in protection.
Lists common faults, possible causes, and corresponding solutions for troubleshooting.
Provides general guidance for diagnosing and resolving common drive abnormalities.
Guidelines for regular maintenance tasks to ensure drive longevity.