EasyManua.ls Logo

Nidec NE200-2S0007GB User Manual

Nidec NE200-2S0007GB
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Serial No -3101A003
User Manual
NE200/NE300
High performance
vector control drive
Scan QR to follow us

Table of Contents

Other manuals for Nidec NE200-2S0007GB

Questions and Answers:

Nidec NE200-2S0007GB Specifications

General IconGeneral
BrandNidec
ModelNE200-2S0007GB
CategoryDC Drives
LanguageEnglish

Summary

Chapter 1 NE200/300 Product Introduction

1.4 Specifications

Detailed technical specifications for NE200 and NE300 drives across various control modes.

1.5 Product Outline, Mounting Dimension

Physical dimensions and outline drawings for product mounting.

1.8 Braking resistor applying guide

Guide for selecting and applying appropriate braking resistors based on model.

Chapter 2 Installation

2.1 Environment

Guidelines for suitable installation environments, avoiding dust, moisture, and extreme temperatures.

Chapter 3 Wiring

3.1 Connection of the Product and Peripheral Devices

Diagram showing the connection of the drive with peripheral devices like power supply, motor, etc.

3.4 Terminal configuration of main circuit

Main circuit wiring terminal configurations for different drive models.

3.5 Attention for Main Circuit Wiring

Important precautions and guidelines for wiring the main circuit to prevent damage and ensure safety.

3.6 Control Terminal Wiring

Wiring diagrams and specifications for the control terminals of NE200 and NE300 drives.

Chapter 4 Operation and Display

4.2 Function code viewing and modification

Explains the three-level menu structure for viewing and modifying function codes.

Chapter 5 Parameters Brief

Group F1: Start and stop control

Parameters for controlling drive start and stop operations, including start modes and DC braking.

Group F3: Vector Control Parameters

Parameters for vector control, including speed and current loops, torque control, and encoder settings.

Group F4: V/F Control Parameters

Parameters for V/F control, including curve settings, torque boost, and slip compensation.

Group F8: PID Parameters (F8)

Parameters for PID control, including setup channels, feedback, gains, and switching conditions.

Group FC: Protection and Fault Parameters

Parameters for motor overload, voltage, current, phase loss, and communication protection.

Group Fd: Communication parameters (Fd)

Parameters for communication settings, including RS485, CAN baud rates, and error detection.

Chapter 6 Parameter description

6.2 Start and stop group (F1)

Parameters for controlling drive start and stop operations, including start modes and deceleration.

6.4 Vector Control Parameters (F3)

Parameters for vector control, including speed and current loops, torque control, and encoder settings.

6.5 V/F Control Parameters (F4)

Parameters for V/F control, including curve settings, torque boost, and slip compensation.

6.9 PID Parameters (F8)

Parameters for PID control, including setup channels, feedback, gains, and switching conditions.

6.13 Protection and fault parameters group (FC)

Parameters for motor overload, voltage, current, phase loss, and communication protection.

6.14 Communication parameters group (Fd)

Parameters for communication settings, including RS485, CAN baud rates, and error detection.

Chapter 7 Fault information and trouble shooting

7.1 Fault information and solutions.

Details various fault codes, possible causes, and troubleshooting solutions for NE200/300 series drives.

7.3 The general fault diagnosis and solutions

General troubleshooting guide for common abnormalities encountered during drive usage.

Chapter 8 Routine Repair and Maintenance

Appendix B: Modbus Communication Protocol

Related product manuals