EasyManua.ls Logo

Nidec NE200-2S0007GB - User Manual

Nidec NE200-2S0007GB
244 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Serial No -3101A003
User Manual
NE200/NE300
High performance
vector control drive
Scan QR to follow us

Table of Contents

Other manuals for Nidec NE200-2S0007GB

Questions and Answers

  • R
    Rebecca RhodesSep 23, 2025
    What to do if Nidec NE200-2S0007GB show EEPROM error?
    • R
      rlopezSep 23, 2025
      If your Nidec DC Drives are showing an EEPROM error: 1. Recover factory defaults if function code parameter writing error. 2. Ask for service from supplier, if EEPROM damaged.
  • H
    hoffmankristyAug 23, 2025
    What causes over current in Nidec NE200-2S0007GB during acceleration and how to fix it?
    • C
      Christopher GomezAug 25, 2025
      Overcurrent during acceleration in Nidec DC Drives can stem from a few reasons. If the acceleration time is too short, increase it. Also, check the input power source for low voltage. Finally, if the drive power rating is too small, choose a drive with higher capacity.
  • M
    Michael FisherAug 25, 2025
    What causes over current at constant-speed in Nidec NE200-2S0007GB DC Drives?
    • T
      timothypriceAug 25, 2025
      If you're experiencing overcurrent at a constant speed with your Nidec DC Drives, several factors could be the cause. Check the load for any abnormal mutations. Also, verify the input power source isn't experiencing low voltage. Ensure your drive has sufficient power capacity. Finally, if you're using closed-loop vector control, inspect the encoder and its wiring for any sudden disconnections.
  • A
    Anita ReynoldsAug 27, 2025
    What to do if Nidec NE200-2S0007GB DC Drives show drive overload?
    • K
      Kelly AllenAug 27, 2025
      If your Nidec DC Drives are showing a drive overload, first check the input power source for low voltage. If the load is too heavy, select a drive with a bigger capacity. If the acceleration is too fast, increase the acceleration time. Also, avoid restarting the motor while it's still turning.
  • S
    Steven RichardsonAug 27, 2025
    What causes over current in Nidec NE200-2S0007GB DC Drives during deceleration?
    • B
      Brandon WolfeAug 27, 2025
      Overcurrent during deceleration in Nidec DC Drives can occur due to several reasons. If the deceleration time is too short, increase it. If there is a large load inertia, add suitable brake devices. Finally, if the drive power rating is too small, choose a higher capacity drive.
  • D
    dmorrisSep 16, 2025
    What to do if Nidec NE200-2S0007GB DC Drives show keypad & control board communication interrupted?
    • R
      Robyn CollinsSep 16, 2025
      If communication between the keypad and control board is interrupted on your Nidec DC Drives, check the connection cable between the keypad and control panel.
  • C
    cooperlaurenSep 13, 2025
    What to do if Nidec NE200-2S0007GB show external terminal fault?
    • C
      Charles CallahanSep 13, 2025
      If your Nidec DC Drives are showing an external terminal fault, check the external input, as the fault likely originates from the external control circuit.
  • V
    veronicawarrenSep 15, 2025
    What to do if Nidec DC Drives show Parameter copy Error?
    • C
      Curtis HamiltonSep 15, 2025
      If your Nidec DC Drives are showing a Parameter copy Error: 1. Shorten the cable between Keypad and control board to reduce interference if too long connection cable between keypad and control board leads to interference in parameters transmission. 2. Before downloading, make sure the parameters match the drive, if the downloading parameters do not match the existed parameters in the drive.
  • M
    Mrs. Kristin BradfordSep 5, 2025
    What to do if Nidec NE200-2S0007GB show ground fault?
    • F
      Frank CruzSep 6, 2025
      If your Nidec DC Drives are indicating a ground fault, it could be due to a short circuit in one of the output phases. Check whether the electric motor insulation is weakening. Also, check whether the wiring between the frequency converter and the electric motor is damaged.
  • B
    Brian WilliamsSep 3, 2025
    What to do if Nidec NE200-2S0007GB show fast current limit fault?
    • A
      Alfred LucasSep 3, 2025
      If your Nidec DC Drives are showing a fast current limit fault, it could be due to a load that is too large or a motor blocked to stall, so decrease the load and check the motor and mechanical part status. If the drive power rating is too small, choose a higher power drive. If the drive output circuit loop is grounded or short-circuited, remove the external fault.

Summary

Chapter 1 NE200;300 Product Introduction

1.4 Specifications

Detailed technical specifications for NE200 and NE300 drives across various control modes.

1.5 Product Outline, Mounting Dimension

Physical dimensions and outline drawings for product mounting.

1.8 Braking resistor applying guide

Guide for selecting and applying appropriate braking resistors based on model.

Chapter 2 Installation

2.1 Environment

Guidelines for suitable installation environments, avoiding dust, moisture, and extreme temperatures.

Chapter 3 Wiring

3.1 Connection of the Product and Peripheral Devices

Diagram showing the connection of the drive with peripheral devices like power supply, motor, etc.

3.4 Terminal configuration of main circuit

Main circuit wiring terminal configurations for different drive models.

3.5 Attention for Main Circuit Wiring

Important precautions and guidelines for wiring the main circuit to prevent damage and ensure safety.

3.6 Control Terminal Wiring

Wiring diagrams and specifications for the control terminals of NE200 and NE300 drives.

Chapter 4 Operation and Display

4.2 Function code viewing and modification

Explains the three-level menu structure for viewing and modifying function codes.

Chapter 5 Parameters Brief

Group F1: Start and stop control

Parameters for controlling drive start and stop operations, including start modes and DC braking.

Group F3: Vector Control Parameters

Parameters for vector control, including speed and current loops, torque control, and encoder settings.

Group F4: V;F Control Parameters

Parameters for V/F control, including curve settings, torque boost, and slip compensation.

Group F8: PID Parameters (F8)

Parameters for PID control, including setup channels, feedback, gains, and switching conditions.

Group FC: Protection and Fault Parameters

Parameters for motor overload, voltage, current, phase loss, and communication protection.

Group Fd: Communication parameters (Fd)

Parameters for communication settings, including RS485, CAN baud rates, and error detection.

Chapter 6 Parameter description

6.2 Start and stop group (F1)

Parameters for controlling drive start and stop operations, including start modes and deceleration.

6.4 Vector Control Parameters (F3)

Parameters for vector control, including speed and current loops, torque control, and encoder settings.

6.5 V;F Control Parameters (F4)

Parameters for V/F control, including curve settings, torque boost, and slip compensation.

6.9 PID Parameters (F8)

Parameters for PID control, including setup channels, feedback, gains, and switching conditions.

6.13 Protection and fault parameters group (FC)

Parameters for motor overload, voltage, current, phase loss, and communication protection.

6.14 Communication parameters group (Fd)

Parameters for communication settings, including RS485, CAN baud rates, and error detection.

Chapter 7 Fault information and trouble shooting

7.1 Fault information and solutions.

Details various fault codes, possible causes, and troubleshooting solutions for NE200/300 series drives.

7.3 The general fault diagnosis and solutions

General troubleshooting guide for common abnormalities encountered during drive usage.

Chapter 8 Routine Repair and Maintenance

Appendix B: Modbus Communication Protocol

Nidec NE200-2S0007GB Specifications

General IconGeneral
BrandNidec
ModelNE200-2S0007GB
CategoryDC Drives
LanguageEnglish

Related product manuals