EasyManua.ls Logo

Nidec RESCUE EZ13 - Page 4

Nidec RESCUE EZ13
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2
Always disconnect electrical power at the fuse box or circuit breaker panel before handling electrical
connections or performing maintenance on this unit. Allow the motor to come to a complete stop and wait
four (4) minutes. This allows the capacitors to discharge any residual voltage for safety.
Double-check to make sure that electrical power is removed and that it cannot be turned on while you are
working on the equipment.
A poor electrical connection can overheat and cause terminal and/or terminal board failures. Examine the
wiring harness quick-connect terminals carefully for any signs of physical deterioration or loose fit to the
terminals on the motor terminal board.
If there is evidence of deterioration or loose fit, remove the quick-connect terminals from the wiring harness
and then connect the harness wires directly to the motor terminal board wiring terminals.
Care must be taken to assure connections are made to the proper terminals and adequate electrical
clearances are maintained.
The control unit on the motor contains hazardous voltage.
Wear safety glasses to inspect the equipment while it is running or while working on equipment.
The motor and control unit are assembled and calibrated as a set. Replacing either the motor or control unit
with other unsuitable parts could drastically affect performance tolerance.
To prevent permanent damage to the unit, only apply nameplate voltage.
Do not apply 230 Vac to the motor when the motor is configured for 115 Vac operation. Refer to page 7.
Do not strike the motor shaft with a hammer or other tool as this may damage the bearings.
Do not operate the motor without the blower wheel attached. Without the blower wheel attached, the motor
will run continuously to a maximum speed and then stop.
Voltage symbols vary among different multimeters and may be displayed as Vac, AC, V, or a V beneath a
wavy line. Select the correct symbol and set the multimeter to the voltage closest to but higher than the
voltage you are measuring.
The RESCUE
®
EZ13 motor is properly packaged for shipment and storage and should be kept in a clean
and dry indoor area.

Related product manuals