Troubleshooting
Problem Cause Remedy
The vacuum cleaner suddenly stops
Clogged primary lter Shake the lter. Replace it if necessary
Clogged vacuum hose Check the vacuum hose and clean it.
Circuit breaker activation
Check the setting.
Check the motor electrical input. Contact
an authorized after-sales service centre if
necessary.
Dust leaks from the vacuum cleaner
The lter is torn Replace it with another of identical type.
Inadequate lter
Replace it with another of a suitable
category and check.
The vacuum cleaner blows instead
of vacuuming
Incorrect connection to the electrical
mains
Ask for assistance from qualied
personnel to perform the correct phase
connection.
See page 8, Starting up chapter
Electrostatic current on the vacuum
cleaner
Non existent or ine󰀩cient grounding
Check all ground connections. Especially
check the inlet.