124
Nokia A032 Advanced User Guide
Traps
The A032 supports a number of traps which are
generated upon specific events and forwarded
to configured managers. The following traps
are supported:
SNMP standard traps
Enterprise-specific traps
The following traps are generated as specified
in the Nokia Private MIB:
Trap Cold Start Generated whenever the unit restarts.
Trap Warm Start Not supported.
Trap Link Down Generated when the LAN or Radio links are disabled.
Trap Link Up Generated when the LAN and/or Radio links are initial-
ized (during restart only).
Trap Authenticate Fail Generated if a bad password in entered in the manage-
ment log on.
Trap EGP Loss Not supported.
Trap Enterprise Supported as below.
A032 Authenticate Fail Generated in the event that a station tries to associate
but is refused due to the fact that the NID Name security
or WEP feature is enabled. Note that this trap is limited
to being generated no more than once every 30 seconds
to prevent flooding due to denial of service attack.
A032 Bridge Down If the bridge/repeater function is active, this trap is gen-
erated when a bridge link is lost.
A032 Management
login
Generated whenever the Management password is suc-
cessfully entered in one of the management utilities.
A032 TFTP Access Generated whenever a TFTP transfer is initiated to or
from the unit.
A032-Adv.book Page 124 Monday, November 13, 2000 10:47 AM