CC Technical Documentation Troubleshooting - RF
RM-11
Issue 2 09/2005 ©2005 Nokia Corporation Confidential Page 9
Observing Tx Output Spectrum on Analyzer
dBm
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
CDMA signal obtained in Local mode by turning modulation ON
CDMA signal on channel 384
Start: 834.020000 MHz Stop: 839.020000 MHz
Res BW: 30 kHz Vid BW: 30 kHz Sweep: 50 ms
6/23/03 3:55:47 PM HP8562E,007
1
Using a spectrum analyzer to observe Tx waveform:
• Enable Local Mode (test jig can be set to Local)
• Select CDMA and Rx/Tx Mode (Tx path enabled)
• Select Rho ON on CDMA Control and Execute
• Adjust the 3 Tx AGC for proper output power level
n
n
o
o