Installation Manual
For models DE / EV 0041 - 3.6 cubic foot, AC / DC electric refrigerators.
For models DE / EV 0061 - 7.0 cubic foot, AC / DC electric refrigerators.
For models DC 0061 - 7.0 cubic foot, DC electric refrigerators.
NORCOLD, Inc.
P.O. Box 4248
Sidney, OH 45365-4248
Part No. 635742B (8/1/2017)
English
Special Requirements for Marine Installations:
These refrigerators are internally wired so that the AC and DC circuits are isolated from each other. If the positive
(+12/24 volts) input is grounded (by cuts in the wire insulation, incorrectly insulated components, etc.) a voltage
potential can be caused throughout the boat, which causes corrosion to form on any metal parts that are exposed
to water.
This condition can be avoided by wiring the boat so that the AC and DC grounds are common and so the wiring is
protected per NNMA CERTIFICATION HANDBOOK (1987). Inspect all wiring to make sure that the insulation is
not damaged and use plastic wire clamps.
One reference for more information on corrosion is:
BOAT AND YACHT CORROSION CONTROL
by Yacht Corrosion Consultants, Inc.
2368 Eastman Ave. #6
Ventura, CA 93003
Norcold Customer Support Dept.
Telephone: 800-543-1219
Fax: 937-497-3183
Web Site: www.norcold.com
Question and Answer IconNeed help?

Do you have a question about the Norcold DE / EV 0061 and is the answer not in the manual?

Norcold DE / EV 0061 Specifications

General IconGeneral
BrandNorcold
ModelDE / EV 0061
CategoryRefrigerator
LanguageEnglish

Summary

Special Requirements for Marine Installations

Safety Awareness

Safety Instructions

Ventilation Requirements

Reverse the door swing (DE / EV0041 models)

Reverse the door swing (DC / DE / EV0061 models)

Install the Refrigerator

Fasten the refrigerator into the enclosure

Securing the refrigerator using mounting screws through flanges.

Connect the Electrical Components

Connect the 120 / 220 volts AC supply

Connecting the AC power cord to a grounded receptacle.

Connect the 12/24 volts DC supply

Connecting the 12/24 volt DC power supply.

Find the minimum wire size to use

Selecting correct wire gauge based on distance.

To protect the DC power supply wiring, install a 15 amp fuse or circuit breaker

Installing a fuse or circuit breaker for DC wiring protection.

Connect the DC power supply wires

Connecting DC power supply wires to correct polarity.