24 Technical design subject to change BU 0750 GB
2.9.8 Cable clamp screws
Some of the cable clamp screws used with SK 750E frequency inverters are different for frame sizes 1 and 2.
The cable entries for the mains input and for the frequency inverter output where the motor is connected are
different (see table below). The two frame sizes are identical however with regard to the cable entries for the
control level, control of the brake resistor and the temperature sensor input.
Mains
Brake resistor
Line to motor
RS485 interface
connect. SK PAR-2H
Temp. sensor
Control level
Shown: air-cooled SK 750E, size 1
Mech. Brake
Cable clamp screws available for frame sizes 1 and 2:
Size
Mains supply
line
Output motor
Control signals
Brake resistor
Temperature
sensor
BG1
M32
M25
3x M25
2x M16
2x M12
BG2
M40
M32
3x M25
2x M16
2x M12
IMPORTANT
Any motor controlled by a SK 750E inverter should be equipped with a temperature sensor.