22 23
Controller “VERSION” report explanation
SMS format Explanation
Ver: version number AirPatrol firmware version
Pump: type,ON/OFF Pump status: type and ON/OFF
Power: ON/OFF(x.xxV) Voltage 5V input and battery voltage (3.50V – 4.20V)
Room: xxC Room temperature in Celsius degrees
GSM: sq, cell
GSM signal strength (0 – 100%) and GSM area info
(1-local network, 5-roaming)
Life: mm.dd Controller run time: months, days
Owner: number Owner mobile phone number
”SETUP” report explanation
SMS format Explanation
Owner: number / All Owner number or All if not defined
Users: number1, number2 / All
User1 and User2 number or All if not
defined
Pump: pump manufacturer’s
name
Chosen pump: Fujitsu
Param: x1,x2,x3, x4
Parameters: 971 (low temperature),
972 (no power), 973 (service), 974 (high
temperature)
AirPatrol command sheets
Heat pump ON/OFF
Restart and Owner number entry
Command SMS Heat pump function
ON Pump ON
OFF Pump OFF
Command SMS Controller function
90
Setup reset (Owner deleted)
and controller restart
93 First time Owner number entry
Commands
Command SMS Heat pump function
AUTO AUTO (+20 °C, fan: NORM)
DRY DRY (+20 °C, fan: NORM)
COOL COOL (+20 °C, fan: NORM)
HEAT HEAT (+20 °C, fan: NORM)
T8 T8 mode