Alarm messages
Alarm messages are only sent to the Owner.
AirPatrol alarm SMS Alarm message
meaning
Message blackout/
alarm treshold
e.g. “LOW TEMPERATURE:
6 °C” (when the limit is 7 °C)
Room temperature is low 24h / +5 K
e.g. “HIGH TEMPERATURE:
31 °C” (when the limit is 30 °C)
Room temperature is high 24h / +5 K
NO POWER 220V power failure Default: 24h
e.g. ”SERVICE: 1 days” Service date Default: 180 days
VERSION New Owner
After setting a new
Owner or changing
Owner
Error messages
“Error command: text”
SMS will be sent if there was an error in your command.
For example, an SMS “cool19max” receives the response
“Error command: cool19max”. Note that AirPatrol will only return your
incorrect command without suggesting a correct one (the error in the
example is the absence of spaces between commands).
“Error userrights: text”
SMS will be sent if the user had no rights for that command.
“Error pump command: text“
SMS means the operation T8 is not available for the specified pump.
When AirPatrol fails to send an SMS it will retry after 1 minute.
Report messages
You can send report requests to AirPatrol about your heat pump status,
controller status and the setup of the controller. Report messages are
sent only to the sender of the request.
SMS
command
you send
SMS
command
function
Response SMS example
STATUS
Pump status
request
Pump: ON; Mode: HEAT; Fan: MAX;
VERSION
Controller
status request
Ver: 1.01b05; Pump: Fujitsu, ON; Power: ON
(4.37V); Room: 19C; GSM: 14,1; Life: 00.05;
Owner: +49550111111;
SETUP Setup request
Owner: +49550111111; Users: All; Pump:
Fujitsu, ON/OFF/NO POWER; Param:
5,24,180,30;
Pump ”STATUS” report explanation
Pump “STATUS” report
SMS Format
Response SMS example
Pump: ON/OFF/NO POWER Pump ON/OFF/NO POWER
Mode: AUTO/DRY/COOL/HEAT/T8 Pump mode
Fan: AUTO/MIN/NORM/MAX Fan speed
Temp: xxC Pump temperature
Room: xxC Room temperature