Heat pump model setup
The pump can be chosen on 2 levels of precision:
1. The precise name of the pump: the manufacturer and the model.
This is recommended for the most efficient operation.
2. Pump manufacturer.
If you only choose the pump manufacturer, functions T8 will not be
checked and the command will be sent even if the pump does not have
T8 mode. If the exact pump model is not listed on our webpage or in this
manual, AirPatrol may or may not work with the heat pump, for which
the AirPatrol manufacturer will not be held responsible.
NB! Heat pump model list and SMS codes can be found at the
end of this manual (page 114).
Alarm messages setup
The Owner can change the default values of the conditions on which
alarm messages are sent. For example, SMS “9713” lowers the room
temperature value at which “LOW TEMPERATURE” SMS is sent from the
default 5 °C to 3 °C.
Setup SMS
command you
send
Response
SMS format
AirPatrol function you activate Default
values
971xx* SETUP
temperature treshold for
„LOW TEMPERATURE” message
5 °C
972xx* SETUP
“NO POWER” message blackout
in hours
24 h
973xx* SETUP
“SERVICE” message interval
in days
180 days
974xx* SETUP
temperature treshold for
„HIGH TEMPERATURE” message
30 °C
* xx marks the place of the numeric value
The „LOW TEMPERATURE” parameters (971) can be between 0 – 16
The “NO POWER” parameters (972) can be between 0 – 48
The “SERVICE” parameters (973) can be between 0 – 360
The „HIGH TEMPERATURE” parameters (974) can be between 17 – 40
When you set parameter 971 to 0, (e.g. you send a text message “9710”) then the
controller will not send you a “LOW TEMPERATURE” message.
When you set parameter 972 to 0, then “NO POWER” message will not be sent.
When you set parameter 973 to 0, then “SERVICE” message will not be sent.
When you set parameter 974 to 0, then “HIGH TEMPERATURE” message will not
be sent.