Specification Summarv 9-5
3. CalcuIating system
electrical power requirements
The total power requirements of the tank, hoses and guns in terms of
total wattage must not exceed the maximum power rating of the system
as given in Table 9.3.
To determine your system’s total power requirements, add up the
individual tank, hose(s) and gun(s) wattages, then compare your total
with the maximum power rating for the system given in Table 9.3.
Remember -
your total must not exceed the figure in the table for your
system.
Tank and hose data are given in Table 9.1. Some gun data is in Table
9.2, the rest is provided in your Not&on Adhesives and Sealants
Equipment Catalog.
TABLE 9.3 - SYSTEM MAXIMUM POWER RATINGS IN WATTS”
Type of Series 2300 Applicator 230 VAC 200 VAC
Systems Systems
380-Y VAC
Systems
Model
2302
(2 hoses maximum)
3,500
2,930
3,160
Model
2304 (4 hoses maximum)
5,250
4,360
4,950
Model
2305 (5 hoses
maximum) 5,250
4,360
4,950
Model
2306 (6 hoses
maximum)
5,250
4,360
4,950
l At 35O’F (177%)
8 No&on Corporation 1994
All Rights Reserved
P/N 106 701A
41-23OOSP - Issued l/94