Operating Parameters
B-4
Part 1032059B
E 2003 Nordson Corporation
Manual 41-DURABLUE-MA-02
Standard (contd)
12 Change Hose 1 Output to Electric Gun Activation
Description:
Changes the proportioned 240 VAC current that is provided to the hose 1
heater to a switched 240 VAC current that is used to activate a
manifold-mounted electric gun.
Value:
0 (disabled)
1 (enabled)
Resolution:
—
Default Value:
0 (disabled)
Format:
—
Use:
Use only when a Nordson manifold-mounted electric is installed and a
switching device is connected to the melter’s switch receptacle. Refer to
the electric gun manual for information on mounting and using the gun.
13 Change Hose 2 Output to Electric Gun Activation
Description:
Changes the proportioned 240 VAC current that is provided to the hose 1
heater to a switched 240 VAC current that is used to activate a
manifold-mounted electric gun.
Value:
0 (disabled)
1 (enabled)
Resolution:
—
Default Value:
0 (disabled)
Format:
—
Use:
Use only when a Nordson manifold-mounted electric is installed and a
switching device is connected to the melter’s switch receptacle. Refer to
the electric gun manual for information on mounting and using the gun.
20 Temperature Units
Description:
Sets the units for temperature display.
Value:
C (degrees Celsius) or F (degrees Fahrenheit)
Resolution:
1 degree
Default Value:
C
Format:
—
Use:
—