How to resolve Fieldbus Communications Failure in Nordson AltaBlue Industrial Equipment?
S
Sonya GonzalezSep 7, 2025
If you're experiencing a Fieldbus Communications Failure with your Nordson Industrial Equipment, it indicates a Fieldbus card failure. Replace the Fieldbus card to resolve this issue.
S
Sandra ScottAug 23, 2025
What to do if material pressure is too high in Nordson AltaBlue Industrial Equipment?
A
Anthony HillAug 25, 2025
If your Nordson Industrial Equipment is showing 'Material Pressure Too High', it could be due to a dirty or defective pressure control valve. Try the following:
* Disassemble and clean the pressure control valve. If cleaning doesn't resolve the issue, replace the valve.
J
Jeremy RoyAug 25, 2025
Why is there no material coming out of my Nordson AltaBlue Industrial Equipment, even though the motor is rotating?
K
Katie LeonAug 26, 2025
If there is no material flow from your Nordson Industrial Equipment, even though the motor is rotating, consider the following:
* The tank might be empty, so fill the tank.
* The filter cartridge could be clogged; clean or replace the filter screen.
* The material supply or suction hole to the pump might be clogged; detach the pump and clean these holes.
* The pressure control valve or safety valve might be defective; replace the respective valve.
* The pump itself could be defective, requiring replacement.
* The pressure control valve setting might be too low; adjust the pressure control valve.
D
Denise RodriguezAug 27, 2025
Why is the material pressure too low in my Nordson AltaBlue?
T
taylorhillAug 27, 2025
If your Nordson Industrial Equipment shows 'Material Pressure Too Low', it could be due to several reasons:
* The pump might be worn, requiring replacement.
* The pressure control valve may not be closing or is dirty, requiring replacement or cleaning.
* The pressure control valve setting might be too low; in this case, set it to the default value.
M
Michael ScottAug 27, 2025
Why is there no material coming out of my Nordson AltaBlue Industrial Equipment and the pump is not rotating?
J
Jeffrey YatesAug 27, 2025
If your Nordson Industrial Equipment is not dispensing material and the pump isn't rotating, it could be due to these reasons:
* The melter may not be ready yet, still in the heat-up phase; wait until it heats up and the green light is on.
* The melter might be under temperature during operation; wait until it heats up.
* The motor may not be enabled; enable the motor.
* The speed (rpm) may not be set; set the speed.
* The system might be in standby mode; exit or wait until the standby period expires.
B
Brianna ConnerAug 29, 2025
Why is my Nordson AltaBlue dispensing too little material?
N
nicolebakerAug 29, 2025
If your Nordson Industrial Equipment is dispensing too little material, here are some potential causes:
* The material supply or pump suction hole may be partially clogged. Detach the pump and clean these holes.
* The filter cartridge may be partly clogged. Clean or replace the filter screen.
* The pressure control valve may be defective. Clean or replace it.
* The processing temperature may be set too low. Correct the temperature setting.
* The pump block may be worn. Replace the pump.
* The safety valve may be defective. Replace the safety valve.
* The pump may be defective. Replace the pump.
* The pressure control valve setting may be too low. Adjust the pressure control valve.
D
Douglas HarrisonSep 13, 2025
Why is there leakage at the pump shaft seal of my Nordson AltaBlue Industrial Equipment?
S
Scott DavidsonSep 13, 2025
If you observe leakage at the pump shaft seal of your Nordson Industrial Equipment, it indicates that the pump shaft seal is worn. You can try tightening the gland bolt or replace the pump to resolve this issue.
A
andersonmichaelSep 8, 2025
What causes Expansion Board Connection Failure in Nordson AltaBlue?
E
edixonSep 8, 2025
If you're experiencing an Expansion Board Connection Failure with your Nordson Industrial Equipment, it means there is a communication failure between the expansion board and the main board. Check the ribbon cable connections between these boards to resolve the issue.
W
William KaufmanSep 5, 2025
What causes Analog-to-Digital Failure Calibration in Nordson Industrial Equipment?
T
Tracie ChapmanSep 6, 2025
If you're experiencing an Analog-to-Digital Failure Calibration issue with your Nordson Industrial Equipment, it means that the hose or applicator RTD analog-to-digital converter could not be calibrated, possibly due to a grounded RTD in the system. To resolve this, replace the hose or applicator. As a temporary measure, you can set the setpoint to zero to avoid the fault. Additionally, consider replacing the main board, ribbon cable, or CPU.
K
Kristin DavisSep 3, 2025
What causes a runaway fault on Nordson AltaBlue?
M
Misty WilliamsSep 3, 2025
If you are experiencing a runaway fault on a zone in your Nordson Industrial Equipment, it means the temperature continues to rise beyond the set point. To resolve this, replace the hose/applicator cordset or replace the mainboard.