Hardware Installation and Setup
3-10
Part 1120130
E 2011 Nordson Corporation
Configuring the Electrical Service
AltaBlue melters are shipped from the factory without an attached power
cable. To configure the melter to function in your facility, you must connect a
properly rated power cable.
The maximum power draw of the melter for any supported service code is 86
A.
Residual Current Circuit Breakers
Local regulations in some geographic areas or industrial branches may
require residual current circuit breakers.
Then observe the following points:
S Permanent installation is required (fixed line voltage connection)
S The residual current circuit breaker is to be installed only between the
power supply and the melter.
S Only residual current circuit breakers sensitive to pulsating current or
universal current (> 30 mA) may be used.
Connecting the Electrical Service
NOTE: The melter must be installed securely (permanent power supply
connection).
WARNING! Operate only at the operating voltage shown on the ID plate.
NOTE: Permitted deviation from the rated line voltage is 10%.
NOTE: The power cable cross‐section must comply with the maximum
power consumption (refer to Section 8, Technical Data).
WARNING! Ensure that cables do not touch rotating and/or hot melter
components. Do not pinch cables and check regularly for damage. Replace
damaged cables immediately!
1. See Figure 3‐7. Route the power cable into the electrical cabinet through
the strain relief on the side of the base.
NOTE: Do not route any input/output wiring through this strain relief.
2. Connect the power cable to the service terminal block as indicated in
table Table 3‐1 and illustrated in Figure 3‐7.
3. Connect the service ground lead to the ground terminal located on the
DIN rail at XL0:PE.