Configuring and Modifying Temperature, Pump and Melter Settings
6-4
Part 1120130
E 2011 Nordson Corporation
Manage Pump Settings
The following table details each temperature settings.
Button Use this to…. Default Range
Pump Speed Manually finetune the pump RPM in either
Manual or GeartoLine mode.
(Recommended)
Min: 18 RPM
Max: 80 RPM
Min: 0 (factory)
Max: 94 RPM
(Factory)
Operation Mode Decide which pump operation mode,
GeartoLine or Manual you want to use.
S Use GeartoLine to deliver adhesive
output at a rate proportional to the speed of
the production line.
NOTE: A linespeed input must be provided if
you want to use the geartoline capability.
S Use manual to:
S Clean or purge the pump.
S Deliver adhesive output at a continuous
rate.
Manual Manual
GeartoLine
Auto Pump Make better use of your time by allowing you to
touch the Master Pump Control button while
the melter status indicates Heating (yellow)
and walk away to perform other tasks.
When the melter status indicates Ready
(green) the pumps automatically start.
NOTE: The Master Pump Control button
changes color to light blue if the Auto Pump
On option is enabled and…
S You touch the Master Pump button
while melter is in the process of heating
the zones to their setpoint
temperatures.
S You take the melter out of Standby
Mode, and you touch the Master
Pump button.
Disabled Disabled
Enabled
Remote Control Enable or Disable a pump from a location
other than the melter console.
Disabled Disabled
Enabled