Troubleshooting
8-15
Part 1120130
E 2011 Nordson Corporation
Material Pressure Too High
Possible Cause Possible Fault / Troubleshooting Corrective Action
1. Pressure control
valve dirty and thus
blocked
Disassemble and clean or replace
2. Pressure control
valve defective
Replace
3. Pressure control
valve set incorrectly
Set to default
Material Pressure Too Low
Possible Cause Possible Fault / Troubleshooting Corrective Action
1. Pump is worn Replace pump
2. Pressure control
valve does not close
any more
Replace
3. Pressure control
valve dirty and thus
clogged
Disassemble and clean or replace
4. Pressure control
valve defective
Replace
5. Pressure control
valve set incorrectly
Set to default