Troubleshooting
8-14
Part 1120130
E 2011 Nordson Corporation
No Material (Motor Rotating)
Possible Cause Possible Fault / Troubleshooting Corrective Action
1. Tank empty Fill tank
2. Filter cartridge
clogged
Clean or replace filter screen
3. Material supply hole
to pump or pump
suction hole clogged
Detach pump and clean supply hole
or suction hole
4. Pressure control
valve defective
Replace pressure control valve
5. Safety valve defective Replace safety valve
6. Pump defective Replace pump
7. Pressure control
valve setting too low
Adjust pressure control valve
Too Little Material
Possible Cause Possible Fault / Troubleshooting Corrective Action
1. Material supply hole
to pump or pump
suction hole partially
clogged
Detach pump and clean supply hole
or suction hole
2. Filter cartridge partly
clogged
Clean or replace filter screen
3. Pressure control
valve defective
Clean or replace
4. Processing
temperature set too
low
Correct temperature setting
5. Pump block is worn Replace pump
6. Safety valve defective Replace safety valve
7. Pump defective Replace pump
8. Pressure control
valve setting too low
Adjust pressure control valve