Service
7-6
Part 1120130
E 2011 Nordson Corporation
Motor and Gear Box
Changing the Motor Lubricant
Remove the gear motor assembly from the melter.
S Use only the stated lubricant or one that has proven to be equivalent
(refer to Lubricant Selection). Using any other lubricant can result in
premature wear and/or damage to the gear box.
S Drain lubricant when warm.
S Properly dispose of the old lubricant according to local regulations.
CAUTION! Never mix different types of lubricants.
Lubricant Changing Interval
Operating temperature < 100 _C / 212 _F:
Every 15000 hours of operation or at least every 4 years.
Lubricant Capacity
Ensure that the upper gears and rolling bearings are properly lubricated.
Lubricant Selection
Lubricant manufacturer
Mineral oil CLP 220
AGIP Blasia 220
ARAL Degol BMB 220 or Degol BG 220
BP Energol GR-XP 220
DEA Falcon CLP 220
ESSO Spartan EP 220 or GP 90
KLÜBER Klüberoil GEM 1-220
OPTIMOL Optigear 220
SHELL Omala Oil 220
TEXACO Geartex EP-A SAE 85 W-90