What causes Expansion Board Connection Failure in Nordson AltaBlue?
E
edixonSep 8, 2025
If you're experiencing an Expansion Board Connection Failure with your Nordson Industrial Equipment, it means there is a communication failure between the expansion board and the main board. Check the ribbon cable connections between these boards to resolve the issue.
M
Michele EvansSep 7, 2025
How to resolve Fieldbus Communications Failure in Nordson AltaBlue Industrial Equipment?
S
Sonya GonzalezSep 7, 2025
If you're experiencing a Fieldbus Communications Failure with your Nordson Industrial Equipment, it indicates a Fieldbus card failure. Replace the Fieldbus card to resolve this issue.
M
Michael MendozaAug 22, 2025
Why is my Nordson Industrial Equipment melter not functioning?
E
Edwin ValdezAug 22, 2025
If your Nordson Industrial Equipment melter is not functioning, here are several potential causes and solutions:
1. **No line voltage:** Connect the line voltage.
2. **Main power switch not switched on:** Turn the main power switch to the ON position.
3. **Defective main power switch:** Replace the main power switch.
4. **Main circuit breaker activated:** Switch on the main circuit breaker.
5. **Main circuit breaker activated again:** Check for a short circuit in the melter or its accessories.
6. **Defective 24 VDC power supply:** Replace the power supply.
7. **Frequent melter shutdowns:** Add a mains filter.
C
Courtney WilliamsSep 4, 2025
How do I fix an Analog-to-Digital Failure on Nordson Industrial Equipment?
N
Nancy GarciaSep 4, 2025
If you're experiencing an Analog-to-Digital Failure with your Nordson Industrial Equipment, it means the RTD analog-to-digital converter has failed. To resolve this, replace the main board or CPU.
K
Kristin DavisSep 3, 2025
What causes a runaway fault on Nordson AltaBlue?
M
Misty WilliamsSep 3, 2025
If you are experiencing a runaway fault on a zone in your Nordson Industrial Equipment, it means the temperature continues to rise beyond the set point. To resolve this, replace the hose/applicator cordset or replace the mainboard.
B
Brittney RiveraSep 1, 2025
What does a brownout mean for Nordson AltaBlue?
L
Linda RiosSep 1, 2025
A brownout in your Nordson Industrial Equipment indicates that the plant power dipped and then recovered. Typically, this requires no action unless the system isn't operating correctly or various messages appear. In such cases, perform a cold stop/start of the melter.
C
Claudia MitchellAug 31, 2025
How to troubleshoot high temperature in Nordson AltaBlue Industrial Equipment zone?
E
Elizabeth Tran DDSAug 31, 2025
If the internal or external temperature for a zone in your Nordson Industrial Equipment has risen above the defined setpoint threshold, it's likely because the actual temperature of the component has risen above the set temperature limit. Check for conditions that may cause an increase in ambient temperature, or consider replacing the component.
M
Mr. Eric HayesAug 30, 2025
How to fix Nordson Industrial Equipment when the temperature drops below the setpoint?
Y
Yesenia CopelandAug 30, 2025
If the internal or external temperature for a zone in your Nordson Industrial Equipment has dropped below the defined setpoint threshold, it's likely because the actual temperature of the component has dropped below the set temperature limit. Check for conditions that may be causing a drop in ambient temperature, or consider replacing the component.
B
Brianna ConnerAug 29, 2025
Why is my Nordson AltaBlue dispensing too little material?
N
nicolebakerAug 29, 2025
If your Nordson Industrial Equipment is dispensing too little material, here are some potential causes:
* The material supply or pump suction hole may be partially clogged. Detach the pump and clean these holes.
* The filter cartridge may be partly clogged. Clean or replace the filter screen.
* The pressure control valve may be defective. Clean or replace it.
* The processing temperature may be set too low. Correct the temperature setting.
* The pump block may be worn. Replace the pump.
* The safety valve may be defective. Replace the safety valve.
* The pump may be defective. Replace the pump.
* The pressure control valve setting may be too low. Adjust the pressure control valve.
M
Michael ScottAug 27, 2025
Why is there no material coming out of my Nordson AltaBlue Industrial Equipment and the pump is not rotating?
J
Jeffrey YatesAug 27, 2025
If your Nordson Industrial Equipment is not dispensing material and the pump isn't rotating, it could be due to these reasons:
* The melter may not be ready yet, still in the heat-up phase; wait until it heats up and the green light is on.
* The melter might be under temperature during operation; wait until it heats up.
* The motor may not be enabled; enable the motor.
* The speed (rpm) may not be set; set the speed.
* The system might be in standby mode; exit or wait until the standby period expires.