Why is the material pressure too low in my Nordson AltaBlue?
T
taylorhillAug 27, 2025
If your Nordson Industrial Equipment shows 'Material Pressure Too Low', it could be due to several reasons:
* The pump might be worn, requiring replacement.
* The pressure control valve may not be closing or is dirty, requiring replacement or cleaning.
* The pressure control valve setting might be too low; in this case, set it to the default value.
J
Jeremy RoyAug 25, 2025
Why is there no material coming out of my Nordson AltaBlue Industrial Equipment, even though the motor is rotating?
K
Katie LeonAug 26, 2025
If there is no material flow from your Nordson Industrial Equipment, even though the motor is rotating, consider the following:
* The tank might be empty, so fill the tank.
* The filter cartridge could be clogged; clean or replace the filter screen.
* The material supply or suction hole to the pump might be clogged; detach the pump and clean these holes.
* The pressure control valve or safety valve might be defective; replace the respective valve.
* The pump itself could be defective, requiring replacement.
* The pressure control valve setting might be too low; adjust the pressure control valve.
S
Sandra ScottAug 23, 2025
What to do if material pressure is too high in Nordson AltaBlue Industrial Equipment?
A
Anthony HillAug 25, 2025
If your Nordson Industrial Equipment is showing 'Material Pressure Too High', it could be due to a dirty or defective pressure control valve. Try the following:
* Disassemble and clean the pressure control valve. If cleaning doesn't resolve the issue, replace the valve.