Hardware Installation and Setup
3-23
Part 1120130
E 2011 Nordson Corporation
Setting Up Gear-to-Line Operation
If you want to use the gear-to-line capability, install a (customer-supplied)
line-speed signal generator to measure the speed of the production line. The
AltaBlue motor control accepts a 0−10 VDC analog input signal.
NOTE: Nordson offers a 0-10 VDC line‐speed signal generator. Refer to
Optional Accessories in Section7, Parts, for the part number.
To use the gear-to-line capability, connect a 0−10 VDC signal from a
customer-supplied line-speed signal generator to the appropriate terminals
on terminal block -17X21 on the electrical enclosure right panel. See Figure
3-14 for the location of terminal block -17X21. Refer to Table 3-6 for the
terminal numbers that correspond to each input/output.