iControlr PROFIBUSr, PROFINETr, DeviceNett, and EtherNet/IPt Generation 4 Slot 9 Gateway
15
Part 1605930−02
E 2020 Nordson Corporation
CommentRangeDescriptionSize
(Bytes)
Address
Offset
IO Module
No.
3 17 1 KV 0−100
3 18 1 μA 0−100
3 19 1 AFC 0−1
3 20 1 Select Charge Mode 0−4
3 21 1 Flow Value/Powder
Setpoint
0−160 Common for Standard
and Prodigy
3 22 1 Atomize Value/Pattern
Flow Setpoint
0−160 Common for Standard
and Prodigy
3 23 1 Assist Air
Compensation
-50−+50 Only for Prodigy
3 24 1 Lookup Table 0−3 Prodigy Only
3 25 1 Not Used
4 26 1 Gun Page No. 0−15 GUI Gun Page No.
5 27 1 %Adjust On/Off 0−1 0=WAIT
5 28 1 %Adjust−Flow -100−+100
5 29 1 %Adjust−Atomize -100−+100
5 30 1 Not Used
6 31 1 Heartbeat 0−255
7 32 1 Send Unicast Msg 0−2 0=WAIT, 1=KV,
2=Flow
7 33 1 Gun Number 1−64
7 34 1 Data Table No. 1−255
7 35 1 Parameter Byte 1 0−255
7 36 1 Parameter Byte 2 0−255
7 37 1 Parameter Byte 3 0−255
7 38 1 Parameter Byte 4 0−255
7 39 1 Parameter Byte 5 0−255
7 40 1 Parameter Byte 6 0−255
7 41 1 Parameter Byte 7 0−255
7 42−43 2 Not Used
8 44−107 64 Preset Number 1−255 For Data Table 14
9 108 1 General Information
Data Type
0−255 0=WAIT, Table 3
9 109 1 Gun Page Number
for Gun General
Information
0−15 GUI Gun Page Number:
associated with next
byte only