iControlr PROFIBUSr, PROFINETr, DeviceNett, and EtherNet/IPt Generation 4 Slot 9 Gateway
23
Part 160593002
E 2020 Nordson Corporation
Gun Monitored Data
Using Modules 10 13
These modules contain monitored gun data for 4 guns, respectively. The
group of 4 guns represented in these 4 IO Modules is defined by the Gun
Page Number value written by the PLC to Module #4 of the Output Image
Table. Use Tables 4 and 7 to identify the correct Address Offsets within the
modules for the desired function.
Table 7 Parameters Contained in Modules 9 12 with Corresponding Address Offsets
Parameter
Description
Explanation Page/Gun1
Module 9
Address
Offset
Page/Gun2
Module 10
Address
Offset
Page/Gun3
Module 11
Address
Offset
Page/Gun4
Module 12
Address
Offset
KV
uA
Actual KV and uA values.
When gun is OFF, Gateway
updates values every 2
seconds.
When gun is ON, Gateway
updates every 0.5 seconds.
KV 0
uA 1
KV 12
uA 13
KV 24
uA 25
KV 36
uA 37
Preset
Number
Displays current preset number
in use by the KV and Flow
control nodes. They are
monitored separately to allow
detection of failure of multicast
message reaching one of its
destination nodes.
Under normal conditions, these
values are the same.
KV node
2
Flow node
8
KV node
14
Flow node
20
KV node
26
Flow node
32
KV node
38
Flow node
44
KV Node
Status Bits
Trigger,
Communica
tion, and
AFC
See Table 8.
Gun Triggered OFF
Bit 0 (LSB) = 0
Gun Triggered ON
Bit 0 (LSB) = 1
KV Node ONLINE
Bit 1 = 0
KV Node OFFLINE
Bit 1 = 1
AFC OFF
Bit 4 = 0
AFC ON
Bit 4 = 1
3 15 27 39
Continued...