iControlr PROFIBUSr, PROFINETr, DeviceNett, and EtherNet/IPt Generation 4 Slot 9 Gateway
17
Part 160593002
E 2020 Nordson Corporation
Module 16
This module contains 8 bytes of information requested through Module 9 as
per Table 3. This module contains the monitored gun parameter values for
4 guns as defined by the second byte of Module 9. The PLC defines which
group of 4 guns is being displayed on the Operator Interface at any given
time by writing the Gun Page No into Module 9, byte 2 of the Output Image
Table. The DSP controller processes this value and places the current
monitored parameters for the group of 4 guns requested by the PLC. If
after requesting certain data the PLC program changes to the IO Module 9
byte 1 to 0 (WAIT state), all the data in the Input Image Table IO Module 16
is reset to 0. The PLC program has to request the data again.
Table 4 Input Image Table
IO Module
No.
Address
Offset
Size
(Bytes)
Description Range Comment
10 0 1 Paged Gun #1KV 0100 KV Monitor
10 1 1 Paged Gun #1μA 0140 μA Monitor
10 2 1 Paged Gun #1Preset 1255 Current Gun Preset
10 3 1 Paged Gun #1On/Off 0x000x13 Trigger State (KV) AFC
State and KV Offline
Node State
10 4 1 Paged Gun #1Type 04 Gun Type
10 5 1 Paged Gun #1Faults 0255 KV Node Faults
10 6 1 Paged Gun #1Flow 0160 Flow Monitor for
Standard/Assist Air
Monitor for Prodigy
10 7 1 Paged Gun #1Atom 0160 Atomize Monitor for
Standard/Pattern Air for
Prodigy
10 8 1 Paged Gun #1Preset 1255 Current Flow Preset
10 9 1 Paged Gun #1On/Off 01 Trigger State (Flow)
10 10 1 Paged Gun #1Faults 0255 Flow Node Faults
10 11 1 Paged Gun #1States 0255 States
1113 1247 36 Paged Gun #2 thru #4 Same Layout as above
14 48 1 Global Status Flags 064 Lockout State
14 49 1 Global Status Flags 064 Alarm State
14 50 1 Global Status Flags 064 Communication Fault
14 51 1 Global Status Flags 064 No 24 VDC Fault
14 52 1 Communication Status 0255 GatewayNodes
Communication Status
14 53 1 Current Page Number 015 Current Parameters
14 5455 2 Future Use
15 56 1 Heartbeat 0255 Heartbeat from Slave
16 57 1 Paged Gun #1
Low Byte
0255 Low Byte Information
16 58 1 Paged Gun #1
High Byte
0255 High Byte Information