EasyManua.ls Logo

Nordson iControl - Page 28

Nordson iControl
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iControlr PROFIBUSr, PROFINETr, DeviceNett, and EtherNet/IPt Generation 4 Slot 9 Gateway
24
Part 160593002
E 2020 Nordson Corporation
Page/Gun4
Module 12
Address
Offset
Page/Gun3
Module 11
Address
Offset
Page/Gun2
Module 10
Address
Offset
Page/Gun1
Module 9
Address
Offset
ExplanationParameter
Description
Gun Type Stores the current gun type
connected to the physical gun
channel.
Valid Gun Codes:
0 = No Gun
1 = Tribo
2 = Sure Coat
3 = Versa
4 = PE Gun
5 = HDLVr
6 = Encore and Encore HD
4 16 28 40
Faults See Table 9.
Contains any fault bits which
have been detected by the
gun’s KV node.
5 17 29 41
Flow
Atom
(or Pattern)
Contains the actual flow rates.
When gun is OFF, Gateway
updates values every 2
seconds.
When gun is ON, Gateway
updates every 0.5 seconds.
Note: See Page 20 for
conversion factors from raw
counts to standard units of flow
rate.
Flow 6
Atom 7
Flow 18
Atom 19
Flow 30
Atom 31
Flow 42
Atom 43
Flow Node
Status Bits
ON/OFF
Stores the current gun trigger
state of the Flow node.
Under normal conditions, these
values are the same as KV
node Trigger states (see
above).
Flow Triggered OFF
Bit 0 (LSB) = 0
Flow Triggered ON
Bit 0 (LSB) = 1
9 21 33 45
Faults Contains any fault bits which
have been detected by the
gun’s Flow node.
See Table 10 for fault bit
definitions.
10 22 34 46
General
Status
Contains the status bits
generated by the gun’s KV and
Flow nodes.
The first two bits indicate the
state of the KV and Flow nodes
regarding their lockout state.
When Lockout is ON, the gun
cannot be trigger ON.
Use Table 11 for bit definitions.
11 23 35 47

Other manuals for Nordson iControl

Related product manuals