iControlr PROFIBUSr, PROFINETr, DeviceNett, and EtherNet/IPt Generation 4 Slot 9 Gateway
25
Part 160593002
E 2020 Nordson Corporation
Table 8 Trigger, AFC, KV Offline StatesAddress Offset #3
States Comment Bit Number
Trigger State 0=Trigger OFF
1=Trigger ON
0(LSB)
KV Node Offline 0=Online
1=Offline
1
Reserved 2
Reserved 3
AFC State 0=AFC OFF
1=AFC ON
4
Reserved 5
Reserved 6
Reserved 7
Table 9 KV Node FaultsAddress Offset #5
Fault Comment Bit Number
μA Alarm 0=No Fault
1=Faulted
0
Fold Back 0=No Fault
1=Faulted
1
Feed Back 0=No Fault
1=Faulted
2
Open Circuit 0=No Fault
1=Faulted
3
Short Circuit 0=No Fault
1=Faulted
4
Hardware 0=No Fault
1=Faulted
5
Alarm (Any) 1=Alarm ON 6
No 24V 1=No 24V Supply 7
Table 10 Flow Node FaultsAddress Offset #10
Fault Comment Bit Number
Communication 1=Heartbeat Lost 0 (LSB)
No 24V 1=No 24V Supply 1
Alarm (Any) 1=Alarm ON 2
Low Flow Fault 1=Faulted 3
Low Atomized Fault 1=Faulted 4
Reserved 5
Valve Detect 1=Atom Valve Fault 6
Valve Detect 1=Flow Valve Fault 7 (MSB)