Troubleshooting
6-24
Part 1024496_06
2014 Nordson Corporation
Continued from previous page....
+
−
Is there voltage on the
downstream side of fuses F3 and
F4 on the main board?
See Figure 6-1.
+
−
Is there voltage across the wires
in the power cable from the
disconnect switch to TB1?
Replace the main board
assembly.
P4/P7 − P/N 1028322.
P10 − P/N 1028323.
Replace fuses F3 and F4.
P/N 1028329.
Replace the power cable.
Starting Condition:
Control panel is not illuminated
T.1