Operating Parameters
B-6
Part 1024496_06
2014 Nordson Corporation
Temperature Control
20
Temperature Units
Description:
Sets the units for temperature display.
Value:
C (degrees Celsius) or F (degrees Fahrenheit)
Resolution:
1 degree
Default Value:
C
Format:
Use:
21
Over Temperature Delta
Description:
The number of degrees that the temperature of any component can
increase over its assigned set-point temperature before an over
temperature fault (F3) will occur.
Value:
5 C (10 F) to 60 C (110 F)
Resolution:
1C
1F
Default Value:
15 C (25 F)
Format:
Use:
22
Under Temperature Delta
Description:
The number of degrees that the temperature of any component can
decrease from its set-point temperature before an under temperature
fault (F2) occurs.
Value:
5 C (10 F) to 60 C (110 F)
Resolution:
1C
1F
Default Value:
25 C (50 F)
Format:
Use:

Table of Contents