Level 2 (parameters, settings by trained
personnel)
Level 3 (basic settings)
Level 1 (normal operation for all operators)
Select
security level
High
Medium
Low
No password
protection
Operation
4-53
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Password Setup (Also Refer to Appendix A)
Assigning New Password, e.g. for Level 1
Level 1 (normal operation for all operators)
Touch key. An input window appears in which the
new password must be entered and confirmed (repeated).
When the passwords have been assigned, a security level must be
selected. Refer to Select Security Level.
Fig. 4-62 V18
NOTE: The passwords must be different for each level and must be at least
one character long and no longer than 16 characters.
NOTE: Every password level also applies to the lower ones. Example: The
password for level 2 also grants access to the features of level 1.
Select security level
High: Password protection is switched on for all three levels.
Medium: Password protection is switched on for level 2 and 3.
Low: Password protection is switched on only for level 3.
No password protection: Password protection is switched off for all three
levels.
No password protection
Fig. 4-63 V19
NOTE: If no keys are touched for 10 minutes, the selected password
protection becomes active again. Then the password prompt appears again
for password-protected features.