0
40
60
80
100
20
100.0
0.0
20 40 60 80 100 [%]
80.0
rpm
%
Line speed for max. pump speed
Max.
pump
speed
Min.
pump
speed
rpm
rpm0
Actual
Line speed for min. pump speed
0.0
%
100.0
0
20 40 60 80 100 [%]
80
bar
%
Line speed for max. pressure
Max.
pressure
Min.
pressure
bar
bar
0
Actual
0
40
60
80
20
Line speed for min. pressure
0.0
%
Operation
4-72
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Motor (contd.)
Screen 4: Pressure Alarms, Speed / Pressure Control
(contd.)
Other Settings
Speeds (Refer to illustration)
Touch key Key-to-line so that the LED lights up (Refer to Fig. 4-83)
Fig. 4-102
Pressure control
Pressure Control - Manual Mode
In manual mode the operator has control over the motors. The pressure is
equal to the setpoint and does not change.
Only pressure sensor A: 5 bar (500 kPa / 73 psi)
Pressure Control - Key-to-line
NOTE: The graph does not change to adapt to the entered values.
Min. pressure: Pressure setpoint when the external line speed signal lies
below the entered value Line speed for min. pressure.
0 bar (0 kPa / 0 psi)
Fig. 4-103
Max. pressure: Pressure setpoint when the external line speed signal
exceeds the entered value Line speed for max. pressure.
80 bar (8000 kPa / 1160 psi)
Line speed for min./max. pressure: Line speed signal value in %, below
or above which the pumps begin to generate the set min./max. pressure.
Max: 100 %
Min: 0 %