2. SPECIFICATION
2.1 Performance data of Swimming Pool Heat Pump Unit
*** REFRIGERANT: R32
UNIT
P31V/32
P31TV/32
P35TV/32
Part nr.
7026971
7026972
7026974
Heating capacity
(A27/W26)
kW
8.5-30.6
8.8-31.2
7.8-35.5
Btu/h
28900-104040
29920-106080
26520-120700
COP
14.3-6.3
15.7-6.1
12.2-5.2
Heating capacity
(A15/W26)
kW
6.4-23.8
6.5-23.6
6.4-27.5
Btu/h
21760-80920
22100-80240
21080-93500
COP
7.8-5.0
8.2-5.0
6.8-4.1
Heating power input
kW
0.53-7.0
0.55-7.0
0.66-8.95
Power Supply
220-240V/50Hz
380V/3N /50Hz
220-240V /50Hz
Compressor Quantity
1
1
1
Compressor
rotary
rotary
rotary
Fan Number
1
1
1
Noise
dB(A)
50-57
50-57
53-59
Water Connection
mm
50
50
50
Water Flow Volume
m3/h
12.5
12.5
14.6
Water Pressure Drop(max)
kPa
23
23
23
Unit Net Dimensions(L/W/H)
mm
See the drawing of the units
Unit Ship Dimensions(L/W/H)
mm
See package lable
Net Weight
kg
see nameplate
Shipping Weight
kg
see package label
Heating: Outdoor air temp: 27/24.3, Inlet water temp:26
Outdoor air temp: 15/12 , Inlet water temp:26
Operating range:
Ambient temperature: -15 43
Water temperature: 9-40