EasyManua.ls Logo

Nortek 212iLW? 242iLW - Wiring an Accessory Relay Board (242 Only); Wiring an Integrated Access Control System Using the Accessory Relay Board

Nortek 212iLW? 242iLW
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 6-050700 X2
212iLW & 242iLW Standalone Keypad
Installation & Programming Manual
5.6 Wiring an Accessory Relay Board
(242 Only)
The accessory relay board contains physical outputs 2, 3, and 4
shown in the table below.
Physical Output Relay Connector
2K2P1
3K3P2
4K4P3
Use the wire harnesses supplied with the relay board to connect to
the relays. The wire colors are shown in the table below.
Wire Color Relay Connection
Gray Normally Closed
Blue Common
Green Normally Open
5.7 Wiring an Integrated Access Control System Using
the Accessory Relay Board
Physical outputs 2, 3, and 4 are defaulted to the alarm shunt,
propped door, and forced door virtual outputs, respectively. Use the
following steps to wire the alarm shunt, propped door alarm, and
forced door alarm.
Figure 9. Wiring the Accessory Relay Board

Related product manuals