40 Configuration
Configuring the system with the Setup Utility
The Setup Utility prompts you through the configuration process by asking a
series of questions. Answer each question or accept the default by pressing
Enter. Each question shows the default in brackets and the acceptable
parameter options in parenthesis.
After powering up, connecting through the console and logging in with the
default user ID and password, enter the following command:
install
Note 1: You must be connected to the master CPU to use the install
script.
Note 2: After running the setup utility, remember to reboot the switch.
A Welcome to ERS 8000 setup utility message appears saying that
you are about to configure initial configuration of the switch. Part of the
data is stored in the file /flash/boot.cfg and part is stored in the runtime
configuration file flash/config.config.
You are asked if you want to continue (y/n)? Type y for yes.
Table 4 "Setup utility prompt descriptions" (page 40) gives the setup utility
prompt descriptions and the corresponding action to perform for each
prompt.
ATTENTION
If you enable high secure (hsecure) mode, when the switch reboots without any
password previously configured, you can use a default password to log on, but
will be prompted to change the password. The new password must follow the
rules mandated by hsecure mode. For more information about hsecure, see
Configuring and Managing Security (NN46205-601; 314721-E).
Table 4
Setup utility prompt descriptions
Prompt Action
Please provide primary
config-file path
[/flash/config.cfg]:
Press Enter to accept the default (/flash/config.cfg), or enter a
different file name for the primary configuration file. To store
your config file on the PCMCIA card, use /pcmcia/config.cfg.
Specifying the path to the file is optional.
Please provide primary image-fil
e path [flash/p80a41xx.img]:
Press Enter to accept the default (p80a41xx.img), or enter a
different file name for the primary image file. Specifying the
path to the file is optional. If the runtime image resides on a
PCMCIA card, you must specify the /pcmcia/filename.
Nortel Ethernet Routing Switch 8600
Quick Start
NN46205-310 01.01 Standard
4.1 21 December 2006