XPM card replacement procedures 1-697
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
NT4X98
in an RSC-S (PCM-30) Model B RMM
(continued)
4 Busy the MTADRIVER by typing
>BSY; BSY INB
and pressing the Enter key.
Example of a MAP display:
5 Set the MAP display to the PM level and post the RMM by typing
>PM;POST RMM rmm_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM where the card is to be removed
Example of a MAP display:
CM MS IOD Net PM CCS LNS Trks Ext Appl
. . . . . . . . . .
TTP
0 Quit POST 1 DELQ BUSYQ DIG
2 Post_ TTP 6–009
3 Seize_ CKT TYPE PM NO. COM LANG STA S R DOT TE RESULT
4 MISC RMM 0 16 MATDRIVER 3 IDL
5 Bsy_
6 RTS_
7 Tst_
8
9 CktInfo
10 CktLoc
11 Hold TTP ID IS: 6–009
12 Next_ TTP:
13 Rls_ LAST CKTN = 1
14 Ckt_ SHORT CLLI IS: MTADRI
15 Trnslvf_ OK, CKT POSTED
16 Stksdr_
17 Pads_
18 Level_