1-868 XPM card replacement procedures
297-8021-547 Standard 14.02 May 2001
NT6X21
in an IOPAC ILCM
(continued)
Summary of card replacement procedure for NT6X21 card in an ILCM
This flowchart summarizes the
procedure.
Use the instructions in the
procedure that follows this
flowchart to perform the
procedure.
At LTP level of the
MAP display, post
the line
Is the line
status ManB?
Y
N
Busy the line card
Replace the line
card
Test the line card
Return the line to
service
Did test pass?
Y
N
Did return to
service pass?
Y
N
Obtain assistance
from maintenance
support group
Obtain assistance
from maintenance
support group
End of procedure