1-874 XPM card replacement procedures
297-8021-547 Standard 14.02 May 2001
NT6X21
in an OPM
(end)
6 Busy the line by typing
>BSY
and pressing the Enter key.
At the OPM cabinet
7 Go to the common replacing a line card procedure in this document. When
you have completed the procedure, return to this point.
At the MAP terminal
8 Test the line card just replaced by typing
>DIAG
and pressing the Enter key.
9 Return the line card to service by typing
>RTS
and pressing the Enter key.
10 Send any faulty cards for repair according to local procedure.
11 Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 13.
12 Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
13 You have successfully completed this procedure.
If the DIAG Do
passed step 9
failed step 12
If RTS Do
passed step 10
failed step 12

Table of Contents

Other manuals for Nortel DMS-100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nortel DMS-100 Series and is the answer not in the manual?

Nortel DMS-100 Series Specifications

General IconGeneral
BrandNortel
ModelDMS-100 Series
CategoryControl Unit
LanguageEnglish

Related product manuals