EasyManua.ls Logo

Novitool Aero - Operation Guide; Power Compatibility and Initial Setup

Novitool Aero
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.flexco.com
—10—
Operation of the Aero
®
Press
Locate position in facility where appropriate voltage and power receptacles are available to
operate the Aero® press.
WARNING! Only use appropriate power.
Depending on the power used, the press might operate in the ‘full power’ mode, which will
have a quicker warm up time, or in the ‘reduced power’ mode. ‘Reduced power’ mode will
take slightly longer to reach the desired dwell temperature.
A1
dwell time
cool down
Full power
Reduced power
temperature
time
A
Aero
®
Power Compatibility for 625, 925, 1225, 1525, 1835, and 2135
Item Code Power Country 625 925 1225 1525 1835 2135 Plug End
09006 1ph 110V, 15A USA R N/A N/A N/A N/A N/A
09007 1ph 110V, 20A USA R R R N/A N/A N/A
09017 1ph 110V, 16A UK R R R N/A N/A N/A
09008 1ph 230V, 10A AUS F R R N/A N/A N/A
09018 1ph 230V, 13A UK F R R R N/A N/A
09009 1ph 230V, 16A EUR F F R R R R
09010 1ph 230V, 30A USA F F F F R R
09011 3ph 230V, 20A USA F F F R R R
09020 3ph 230V, 30A USA F F F F R R
09012 3ph 400V +N EUR F F F F F F
09013 3ph 400V no N EUR N/A N/A N/A F F F
09014 3ph 460V USA N/A N/A N/A F F F
(F= full power operation, R= reduced power operation)