—17—
Operation of the Aero
®
Press
Automatic splice process
a. Both internal air compressor and heating will
begin.
b. View display output screen to monitor
splicing cycle progress. Screen message for
dierent splicing stages:
NOTE: During all phases the temperature
display will toggle between set value and
actual.
i. Preheat heat up (if preheat is chosen)
1. Pressure
2. Top temperature
3. Bottom temperature
ii. Preheat dwell time (if preheat is chosen)
1. Time
2. Top temperature
3. Bottom temperature
iii. Splicing heat up
1. Pressure
2. Top temperature
3. Bottom temperature
iv. Splicing dwell time
1. Time
2. Top temperature
3. Bottom temperature
v. Cool down
1. Fans start
2. Top temperature
3. Bottom temperature
A11
START the splice process.
a. Prior to pushing the green START button,
always check:
i. Are all four press connector bolts engaged?
ii. Are all settings correct?
b. If yes, push the green START button and
automatic splice process will start.
A10
Cycle Start Button