OPERATION 9. HOW TO USE APPLIED FUNCTIONS (SWITCH OUTPUT)
Deletes the DOG1
9-4-1. Deletes by the Dog Units
The deletion method by the dog unit is following:
1. Selects intended dog.
2. Set the same value to ON and OFF angles.
The following procedures perform deletion.
The deletion is set in the switch setting (SET) mode.
For mode selection methods, refer to the “7-6-1. Selects the Switch Setting (SET) Mode”.
Selects the program number.
Selects the program number by
pressing [+] or [-] key of PROGRAM.
VS-5F and VS-5F-1 don’t have any program
function. Starts the operation from ②.
Selects the switch number.
Selects the switch number by
pressing [+] or [-] key of SW / PRM.
Selects the dog number.
Selects the dog number by pressing
[+] or [-] key of the dog.
Inputs the same value for ON angle and OFF angle.
Inputs to ON angle which is same value as OFF angle
by pressing [+] or [-] key of POSITION, and then
the value blinks in the POSITION display area.
If [CLR] key is pressed in this timing, the deletion by
the dog unit will be canceled.
Deletes the dog.
Presses [SET] key, and then POSITION
display area turns ON.
The dog is deleted.
SW-ON LED
SET LED
By 10°
units
By 0.5°
SW-ON LED
is ON
Displays by 0.5°units
Decimal point is ON : 0.5°
Decimal point is OFF : 0.0°