233970 (Page 38) 10/11 (A13)
Changing the Floor-Tool Blades
! !
ALWAYS ENSURE THAT THE BATTERY IS DISCONNECTED PRIOR TO ANY
MAINTENANCE
machine (Fig 41).
(Fig 43).
Remove the blade holder (Fig 44).
location lugs.
(Fig 46)
Ensure the slotted blade goes to the front of the
1. Floor-tool main body
2. Blade carrier
3. Rear blade
4. Front blade (slotted)
5. Retaining Knobs x 4
1
2
3
5
4
Fig 41
Fig 42
Fig 43 Fig 44 Fig 45
Fig 46
Fig 47
The blades are designed to be reversible, thus
Use Genuine NUMATIC spare parts.
use
Replacement Blade Set (606261)