Select the steam icon and confirm with the
rotary switch.
Turn the rotary switch to select the required
pressure / temperature for the boiler (see the
table on the following page) and then press the
switch to confirm the setting.
BOILER SETPOINT (T3 version only):
The display shows:
Boiler setpoint
93.493.4
Max
93.4
MaxMax
Boiler temperature
Boiler setpoint
Select the coffee boiler to be adjusted and con-
firm by pressing the rotary switch.
Boiler 1 example
Turn the rotary switch to select the required
temperature for the group; press it to confirm
the setting.
Group setpoint
93.8
94.0
92.8
93.8
92.892.0
Group temperature
Group setpoint
3
BOILER OFFSET ADJUSTMENT:
From the screen:
Hold down the washing key to access
offset and boiler temperature adjustment.
The next screen will be:
Use the rotary switch to select the coffee boiler
for offset adjustment and press it to proceed.
Also use the rotary switch to set the offset value
for the group and then press the switch to con-
firm.
At this point it is possible to adjust the offset of
other groups with the same procedure or select
Menu
or
Home
.
This setting is reserved to qualified service
engineers.
Boiler setpoint
93.493.4
Max
93.4
MaxMax
Boiler temperature
Boiler setpoint